FacebookTwitter

 

Caso Clínico

Drug-eluting balloon angioplasty for pulmonary vein re-stenosis secondary to multiple atrial ablations

Marcelo Montero, Juan Arellano, Juan Fernández, Alejandro Palacios

Revista Argentina de Cardioangiologí­a Intervencionista 2025;(2): 0068-0070 | Doi: 10.30567/RACI/20252/0068-0070


Introduction. Patients with atrial fibrillation undergoing atrial ablation may develop pulmonary vein stenosis.
Clinical case. The patient was a 56-year-old man with a history of atrial fibrillation treated three times with pulmonary vein (PV) ablation and NYHA class II dyspnea that developed after the last intervention. He was admitted one year later with an exacerbation of atrial fibrillation and progression of dyspnea. CT angiography revealed severe stenosis of the left pulmonary veins, leading to a decision for repeat ablation and pulmonary vein angioplasty with stent placement. After 26 months, he presented with similar clinical symptoms. Imaging studies revealed pulmonary vein restenosis; drug-eluting balloon angioplasty was subsequently performed with a satisfactory outcome.
Conclusion. Drug-eluting balloon angioplasty is an effective treatment for pulmonary vein restenosis after prior stent intervention.


Palabras clave: pulmonary vein restenosis, stenting angioplasty, ablation, drug-eluting balloon.

Introducción. Los pacientes con fibrilación auricular intervenidos con ablación auricular pueden intercurrir con estenosis de venas pulmonares.
Caso clínico. Paciente masculino de 56 años, con antecedente de fibrilación auricular tratado en tres ocasiones con ablación de venas pulmonares (VP) y disnea CFII instaurada tras la última intervención. Ingresa después de un año, con reagudización de fibrilación auricular y progresión de disnea, tras evaluación angiotomográfica se advierte estenosis severa de venas pulmonares izquierdas, por lo que se decide nueva ablación y angioplastia con stents de VP. Tras 26 meses presenta cuadro clínico de similares características, evidenciando hallazgos imagenológicos de reestenosis de VP; finalmente se realiza angioplastia con balón liberador de drogas, evolucionando satisfactoriamente.
Conclusión. La angioplastia con balón liberador de drogas como tratamiento con resultados eficientes en un caso de reestenosis de venas pulmonares, tras intervención con stents.


Keywords: reestenosis de venas pulmonares, angioplastia con stents, ablación, balón liberador de drogas.


Los autores declaran no poseer conflictos de intereses.

Fuente de información Colegio Argentino de Cardioangiólogos Intervencionistas. Para solicitudes de reimpresión a Revista Argentina de Cardioangiología intervencionista hacer click aquí.

Recibido 2025-05-20 | Aceptado 2025-06-29 | Publicado


Licencia Creative Commons
Esta obra está bajo una Licencia Creative Commons Atribución-NoComercial-SinDerivar 4.0 Internacional.

Figura 1. The ablation electrodes are visible; these were used to locate the pulmonary veins and th...

Figura 2. CT angiography. A) Left superior pulmonary vein stenosis. B) Left inferior pulmonary vein...

Figura 3. Drug-eluting peripheral balloon angioplasty is shown for in-stent restenosis in the pulmon...

Introduction

Catheter ablation has become the therapeutic alternative in cases of atrial fibrillation (AF), using energy to isolate the pulmonary veins (PVs) by radiofrequency. As the tissue is ablated through thermal injury, fibrosis and scarring develop and extend deeply into the treated pulmonary vein from the ostium, leading to vascular lumen stenosis2, 4-5. Pulmonary vein stenosis is usually diagnosed between 3 to 5 months after the catheter procedure, and its incidence has substantially decreased from 22.9% (range 3.4 to 42.4%) to 0.85% (range 0.7 to 1%) as a result of antral isolation, circumferential ablation, three-dimensional mapping, and the use of intracardiac ultrasound3, 5. Clinically, PV stenosis may present with exertional dyspnea, cough, pleuritic pain, and hemoptysis, and it can be progressive, causing irreversible damage to the pulmonary parenchyma, pulmonary hypertension, and heart failure. Therapeutic management includes percutaneous intervention with balloon angioplasty (BA) or pulmonary vein stenting (PVS). Cases of restenosis can occur within three years from the last intervention1-2. The use of drug-eluting balloons has shown significant results and is considered an option for in-stent restenosis, a complex problem, and for the treatment of small vessel disease6-7.

Case description

A 56-year-old man, with a history of arterial hypertension, gastric bypass, and atrial fibrillation treated on three occasions with extensive ablation of the right PVs, was admitted again with New York Heart Association (NYHA) class II clinical dyspnea, which—he reported—had been present since the last ablation one year before. A CT angiography revealed left PV stenosis. A choice was made to conduct another AF ablation and stent angioplasty of the left PVs (Figure 1). Extensive antral isolation of the right PVs was performed with point-by-point application of 40 watts on the anterior wall and 30 watts on the posterior wall, reaching up to 40 °C, guided by VISITAG SURPOINT®. Isolation of all four PVs was confirmed.

Subsequently, angioplasty was performed by placing 7 × 56-mm Biotronik Dynamic® stents (8 ATM) in each of the superior and inferior left PV branches, using transesophageal Doppler echocardiography to confirm proper opening and absence of gradient.

After 26 months, the patient was readmitted for NYHA class II–III dyspnea; a new CT angiography showed calcified PV ostia with associated periostial thickening.

The left superior pulmonary vein (LSPV) had an approximately 54-mm long ostial stent, extending from 10 mm inside the atrial cavity to an inferior secondary branch. The vein was patent but showed focal eccentric restenosis. The minimal luminal area was 7 mm2, for a maximal luminal area of 26 mm2, with a 5.5-mm reference diameter at 17 mm from the atrial end. The left inferior pulmonary vein (LIPV) had an ostial stent extending approximately 8 mm into the atrial cavity; imaging showed severe concentric focal restenosis at the ostium (Figure 2). The right PVs showed no stenosis, and there were no signs of thrombosis. A choice was made to conduct another angioplasty using drug-eluting balloons: Passeo Lux™ Biotronik OTW, 0.018”, 7 × 40 mm × 2 (Paclitaxel 3.0 μg/mm2, polymer: Paclitaxel and butyryl-tri-hexyl citrate BTHC) (Figure 3). The procedure was completed without complications, followed by medical treatment with dual antiplatelet therapy. The patient evolved favorably and remained in sinus rhythm and without dyspnea during follow-up.

Discussion

Pulmonary vein (PV) ablation has become an important therapeutic approach in the treatment of cardiac arrhythmia, with stenosis being a serious, infrequent, but clinically relevant complication. Stenosis is defined as a reduction of 3 mm or more in its diameter. It depends particularly on the ablation techniques applied and is higher with segmental or focal ablation at the PV ostium, around 21%, compared to circumferential ablation and antral isolation, for which it is estimated at only 0.6%1. Therapeutic management includes percutaneous intervention with balloon angioplasty (BA) or pulmonary vein stenting (PVS). After evaluating a systematic review reporting eight observational studies with 487 patients with inclusion criteria, the primary outcome of restenosis requiring reintervention occurred in 196 of 325 veins in the BA group and in 111 of 443 veins in the PVS group. Compared to PVS, BA was associated with a significantly higher risk of restenosis (odds ratio [OR] = 2.91; 95% confidence interval [CI]: 1.15-7.37. PAG=0.025; I2= 79.2%)1, 2. The mechanisms involved in PV restenosis after an initially successful recanalization are not fully understood but may relate to a combination of neointimal hyperplasia, fibrosis, and thrombus formation. Drug-eluting balloons (DEB) have demonstrated safety and efficacy for the treatment of restenosis. Late lumen loss during follow-up is consistently low (< 0.2 mm), and no thrombotic events have been reported when using DEBs. The European Society of Cardiology has given DEBs a class IIa, level B recommendation for the treatment of in-stent restenosis6, 7.

Conclusion

The use of DEB in restenosis was considered in this patient as a safe and beneficial alternative. In correlation with the evidence, it proves to be an innovative method promising significant clinical results. It constitutes an evolving technology of great interest due to its potential applications in various coronary, cardiac, and extracardiac interventions6, 7.

  1. Campo-Rivera N, Negrete-Salcedo A, Tenorio-Tascón C, Rodríguez-Martínez A, Escobar-Rojas W. Angioplastia con balón de venas pulmonares por estenosis tras ablación percutánea de fibrilación auricular. Revista Colombiana De Cardiología 2022;28(5), vol. 28, no 5, p. 473-477.

  2. Agasthi P, Sridhara S, Rattanawong P, Venepally N, Chao C, et al. Safety and efficacy of balloon angioplasty compared to stent-based-strategies with pulmonary vein stenosis: a systematic review and meta-analysis. World Journal of Cardiology, 2023, vol. 15, no 2, p. 64.

  3. Ogawa T, Yamashita S, Oseto H, Yokoyama M, Itakura R, et al. Pulmonary vein angioplasty for pulmonary vein stenosis after ablation therapy for atrial fibrillation – a report of 7 cases –. Circulation Journal 2022;86(8):1229-1236.

  4. Fink T, Vogler J, Proietti R, Sciacca V, Heeger C, et al. Antithrombotic therapy after angioplasty of pulmonary vein stenosis due to atrial fibrillation ablation: a two‐center experience and review of the literature. Journal of Arrhythmia 2022;38(6):1009-1016.

  5. Fender E, Widmer R, Hodge D, Cooper G, Monahan K, et al. Severe pulmonary vein stenosis resulting from ablation for atrial fibrillation. Circulation 2016;134(23):1812-1821.

  6. Kleber F, Mathey D, Rittger H, Scheller B. How to use the drug-eluting balloon: recommendations by the german consensus group. EuroIntervention 2011;7(K): K125-K128.

  7. Choo G-H. Drug-eluting balloons: future potential indications and applications. EuroIntervention 2011;7: K112-K118.

Autores

Marcelo Montero
Fellow in the Department of Hemodynamics. Sanatorio de la Trinidad Palermo. Buenos Aires City. Argentina.
Juan Arellano
Attending Physician at the Department of Hemodynamics. Sanatorio de la Trinidad Palermo. Buenos Aires City. Argentina.
Juan Fernández
Attending Physician at the Department of Hemodynamics. Sanatorio de la Trinidad Palermo. Buenos Aires City. Argentina.
Alejandro Palacios
Chief of the Department of Hemodynamics. Sanatorio de la Trinidad Palermo. Buenos Aires City. Argentina.

Autor correspondencia


.

Correo electrónico:

Para descargar el PDF del artículo
Drug-eluting balloon angioplasty for pulmonary vein re-stenosis secondary to multiple atrial ablations

Haga click aquí


Para descargar el PDF de la revista completa
Revista Argentina de Cardioangiología intervencionista, Volumen Año 2025 2

Haga click aquí

Revista Argentina de Cardioangiología intervencionista
Issue # 2 | Volumen 15 | Año 2025

Etiquetas

pulmonary vein restenosis, stenting angioplasty, ablation, drug-eluting balloon

Tags

reestenosis de venas pulmonares, angioplastia con stents, ablación, balón liberador de drogas

Titulo
Drug-eluting balloon angioplasty for pulmonary vein re-stenosis secondary to multiple atrial ablations

Autores
Marcelo Montero, Juan Arellano, Juan Fernández, Alejandro Palacios

Publicación
Revista Argentina de Cardioangiología intervencionista

Editor
Colegio Argentino de Cardioangiólogos Intervencionistas

Fecha de publicación
2025-06-30

Registro de propiedad intelectual
© Colegio Argentino de Cardioangiólogos Intervencionistas

Reciba la revista gratis en su correo


Suscribase gratis a nuestra revista y recibala en su correo antes de su publicacion impresa.


Colegio Argentino de Cardioangiólogos Intervencionistas
Viamonte 2146 6° (C1056ABH) Ciudad Autónoma de Buenos Aires | Argentina | tel./fax +54 11 4952-2117 / 4953-7310 |e-mail revista@caci.org.ar | www.caci.org.ar

Revista Argentina de Cardioangiologí­a Intervencionista | ISSN 2250-7531 | ISSN digital 2313-9307

La plataforma Meducatium es un proyecto editorial de Publicaciones Latinoamericanas S.R.L.
Piedras 1333 2° C (C1240ABC) Ciudad Autónoma de Buenos Aires | Argentina | tel./fax +54 11 5217-0292 | e-mail info@publat.com.ar | www.publat.com.ar

Meducatium versión 2.2.2.4 ST